Přidejte soubory projektu.
parent
4c80803656
commit
22cecc2650
|
@ -0,0 +1,13 @@
|
|||
<Project Sdk="Microsoft.NET.Sdk">
|
||||
|
||||
<PropertyGroup>
|
||||
<TargetFramework>net8.0</TargetFramework>
|
||||
<ImplicitUsings>enable</ImplicitUsings>
|
||||
<Nullable>enable</Nullable>
|
||||
</PropertyGroup>
|
||||
|
||||
<ItemGroup>
|
||||
<PackageReference Include="System.Device.Gpio" Version="3.1.0" />
|
||||
</ItemGroup>
|
||||
|
||||
</Project>
|
|
@ -0,0 +1,25 @@
|
|||
|
||||
Microsoft Visual Studio Solution File, Format Version 12.00
|
||||
# Visual Studio Version 17
|
||||
VisualStudioVersion = 17.8.34309.116
|
||||
MinimumVisualStudioVersion = 10.0.40219.1
|
||||
Project("{FAE04EC0-301F-11D3-BF4B-00C04F79EFBC}") = "Libs_SequentMicrosystems", "Libs_SequentMicrosystems.csproj", "{C3DEDD92-2AF1-448F-B500-2009E9EE88F5}"
|
||||
EndProject
|
||||
Global
|
||||
GlobalSection(SolutionConfigurationPlatforms) = preSolution
|
||||
Debug|Any CPU = Debug|Any CPU
|
||||
Release|Any CPU = Release|Any CPU
|
||||
EndGlobalSection
|
||||
GlobalSection(ProjectConfigurationPlatforms) = postSolution
|
||||
{C3DEDD92-2AF1-448F-B500-2009E9EE88F5}.Debug|Any CPU.ActiveCfg = Debug|Any CPU
|
||||
{C3DEDD92-2AF1-448F-B500-2009E9EE88F5}.Debug|Any CPU.Build.0 = Debug|Any CPU
|
||||
{C3DEDD92-2AF1-448F-B500-2009E9EE88F5}.Release|Any CPU.ActiveCfg = Release|Any CPU
|
||||
{C3DEDD92-2AF1-448F-B500-2009E9EE88F5}.Release|Any CPU.Build.0 = Release|Any CPU
|
||||
EndGlobalSection
|
||||
GlobalSection(SolutionProperties) = preSolution
|
||||
HideSolutionNode = FALSE
|
||||
EndGlobalSection
|
||||
GlobalSection(ExtensibilityGlobals) = postSolution
|
||||
SolutionGuid = {160033F0-C347-43EF-9B6A-D67DDFC7BF91}
|
||||
EndGlobalSection
|
||||
EndGlobal
|
|
@ -0,0 +1,57 @@
|
|||
using System;
|
||||
using System.Device.Gpio;
|
||||
using System.Device.I2c;
|
||||
|
||||
|
||||
namespace Libs_SequentMicrosystems
|
||||
{
|
||||
public class RTDStackLevelReader
|
||||
{
|
||||
public readonly byte DEVICE_ADDRESS = 0x40;
|
||||
public readonly byte RTD_RESISTANCE_ADD = 59;
|
||||
|
||||
/// <summary>
|
||||
/// Read Single Resistance
|
||||
/// </summary>
|
||||
/// <param name="stack">Level on Stack 0-7</param>
|
||||
/// <param name="channel">Chanel on stack layer 1-8</param>
|
||||
/// <returns>Resistance of selected element</returns>
|
||||
/// <exception cref="ArgumentException"></exception>
|
||||
/// <exception cref="IOException"></exception>
|
||||
public float Get(byte stack, byte channel)
|
||||
{
|
||||
if (stack < 0 || stack > 7)
|
||||
throw new ArgumentException("Invalid stack level");
|
||||
|
||||
if (channel < 1 || channel > 8)
|
||||
throw new ArgumentException("Invalid channel number");
|
||||
|
||||
float val = -273.15f;
|
||||
|
||||
try
|
||||
{
|
||||
using (I2cDevice i2c = I2cDevice.Create(new I2cConnectionSettings(1, DEVICE_ADDRESS + stack)))
|
||||
{
|
||||
byte[] buffer = new byte[4];
|
||||
i2c.WriteByte((byte)(RTD_RESISTANCE_ADD + (4 * (channel - 1))));
|
||||
i2c.Read(buffer);
|
||||
val = BitConverter.ToSingle(buffer, 0);
|
||||
}
|
||||
}
|
||||
catch (IOException e)
|
||||
{
|
||||
throw new IOException($"Fail to communicate with the RTD card with message: \"{e.Message}\"");
|
||||
}
|
||||
|
||||
return val;
|
||||
}
|
||||
|
||||
|
||||
//public float[] GetStack(byte stack)
|
||||
//{
|
||||
|
||||
//}
|
||||
|
||||
|
||||
}
|
||||
}
|
Loading…
Reference in New Issue